AmphoMag
Overview
AmphomagAmphoMag is a universal spill neutralizer and sorbent used to safely adsorb and treat hazardous chemical releases, including acids, bases, and organic liquids. It includes a pH color indicator.
AmphoMag is produced by Premier Magnesia, LLC and is a registered trademark owned by Premier Magnesia, LLC,
Color Change Indicator
A built in multi-range pH indicator is included.included in AmphoMab After application, it turns red for acids and blue for bases. As Amphomag® neutralizes the spill, the color gradually changes to yellow or green.
Packaging
Amphomag® is packaged in 3 lb. shaker bottles, 50 pound bags and 50 pound totes.
PHOTO: AmphoMag 50lb bag, 3lb shake, and 50lb tote.
Application and Safety Considerations
Acids
All acids will generate heat when neutralized with Ampho-MagTM.AmphoMag. Nitric and Perchloric acids will produce more heat than other acids, which may result in some splattering. In order to reduce the potential for splattering, apply a large excess of Ampho-MagTM and completely cover spill with a thick layer of Ampho- MagTM.AmphoMag. When Ampho-MagTM is applied to the acid spill, the pH indicator should turn red. This indicates that the spill is still acidic and more Ampho-MagTMAmphoMag needs to be applied to time is required until a yellow/green color indicates neutralization is complete.
Ampho-MagTM will generate heat during a neutralization reaction, especially with acids.
Alkalis (Bases)
Neutralization of alkalis with Ampho-MagTM will generate little heat. It is unlikely any splattering will occur. When Ampho-MagTMAmphoMag is applied to the alkali the pH indicator should turn blue. This indicates that the spill is still alkaline and more Ampho-MagTMAmphoMag should be applied until a yellow/green color indicates that neutralization is complete.
Amount Required
| Spilled Material (1 gallon) | Amount of AmphoMag Needed |
| 94% Sulfuric Acid | 14 pounds |
|
50% caustic Soda |
23 pounds |
| 70% Nitric Acid | 6 pounds |
| 35% Hydrochloric Acid | 5 pounds |
| 85% Phosphoric Acid | 12 pounds |
Do not apply to AmphoMag spill in a confined space or closed container such as a drum or pail, gases generate may over-pressurize the vessel resulting in a violent failure.
Solvents and Other Liquids
Ampho-MagTMAmphoMag acts as a sorbent in the case of these liquids and will not render the spill non-hazardous. No adverse reactions with organic solvents are known. If the organic solvent contains appreciable amounts of water, then some heat can be generated. Apply Ampho-MagTMAmphoMag until the spill is dry. Since organic solvents are generally not acidic nor alkaline, the pH indicator is non-functional under these circumstances.
Precautions
Ampho-MagTM will generate heat during a neutralization reaction, especially with acids.
Do not apply to a spill in a confined space such as a drum or pail.
Attachments
AmphoMag Application Guidelines
AmphoMag Application Guidelines.pdf
Safety Data Sheets
Ampho Mag Safety Data Sheet.pdf